80kA Pluggable Surge Protective Device SPD
- Prosurge
- China
- Within 25 days
- 10kpcs per month
Type 2 AC surge arrester designed for low-voltage power supply system protection against surges at the boundaries from lightning protection zone 1-2 and higher.
Comply with IEC 61643-11, UL1449-4th, apply to TT and TN systems (“3+1” circuit).
High Discharge Capacity with 8/20μs waveform, Imax 80kA
18mm per pole, consist of pluggable module and base, easy maintenance
Reliable supervision due to disconnection device
Visual status indication and remote signal contact available.
Part No. | V80P/150(-S) | V80P/175(-S) | V80P/275(-S) | V80P/320(-S) | |
In accordance with | IEC61643-11:2011; UL1449-4th | ||||
Category IEC/VDE | II/ C | ||||
Max. continuous operating voltage (AC/DC) Uc | 150/200 | 175/225 | 275/350 | 320/420 | |
Nominal discharge current(8/20) In | 40kA | ||||
Max. discharge current(8/20) Imax | 80kA | ||||
Voltage protection level Up | @In | <0.8kV | <0.8kV | <1.5kV | <1.8kV |
Response time | ≤25 ns | ||||
Follow current | No | ||||
Backup fuse(only required if not already provided in mains) | 200A gL/gG | ||||
Operating temperature range | - 40ºC ~ + 80ºC | ||||
Cross-section of connection wire | Single-strand 35mm2; multi-strand 25mm2 | ||||
Mounting | 35mm DIN-rail in accordance with EN 50022/DIN46277-3 | ||||
Enclosure material | thermoplastic; extinguishing degree UL94 V-0 | ||||
Degree of protection | IP20 | ||||
Installation width | 1 module, DIN 43880 | ||||
Thermal disconnector | Internal green – normal ; red - failure | ||||
Remote alarm contact | Optional | ||||
Approvals, Certifications | CE | ||||
Additional data for Remote Alarm Contacts | |||||
Remote alarm contact type | Isolated Form C | ||||
Switching capability Un/In | AC: 250V/0.5A DC: 250V/0.1A; 125V/0.2A; 75V/0.5A | ||||
Max. Size of connecting wire | Max. 1.5mm2(or # 16AWG) |
Prewired Multi-pole SPD
Part No. |
Pole |
Power System | Nominal Voltage (phase voltage) Un | Max. Operating Voltage Uc | Max. Discharge Current (8/20μs) Imax | Voltage protection Level Up |
Diagram |
DS80P/150-2V-S | 2 | Single phase 2W+G | 120~127Vac | 150Vac | 80kA | L/N-G: 0.8kV | 4 |
DS80P/180-2V-S | 2 | Single phase 2W+G | 120~127Vac | 180Vac | 80kA | L/N-G: 0.8kV | 4 |
DS80P/275-2V-S | 2 | Single phase 2W+G | 220~230Vac | 275Vac | 80kA | L/N-G: 1.5kV | 4 |
DS80P/320-2V-S | 2 | Single phase 2W+G | 240~277Vac | 320Vac | 80kA | L/N-G: 1.8kV | 4 |
DS80P/150-(V+T)-S | 2 | Single phase 2W+G | 120~127Vac | 150Vac | 80kA | L-N: 0.8kV, N-PE: 0.8kV | 3 |
DS80P/180-(V+T)-S | 2 | Single phase 2W+G | 120~127Vac | 180Vac | 80kA | L-N: 0.8kV, N-PE: 0.8kV | 3 |
DS80P/275-(V+T)-S | 2 | Single phase 2W+G | 220~230Vac | 275Vac | 80kA | L-N: 1.5kV, N-PE: 1.5kV | 3 |
DS80P/320-(V+T)-S | 2 | Single phase 2W+G | 240~277Vac | 320Vac | 80kA | L-N: 1.8kV, N-PE: 1.5kV | 3 |
DT80P/150-3V-S | 3 | Three phase 3W+G | 120~127Vac | 150Vac | 80kA | L-G: 0.8kV | 2 |
DT80P/180-3V-S | 3 | Three phase 3W+G | 120~127Vac | 180Vac | 80kA | L-G: 0.8kV | 2 |
DT80P/275-3V-S | 3 | Three phase 3W+G | 220~230Vac | 275Vac | 80kA | L-G: 1.5kV | 2 |
DT80P/320-3V-S | 3 | Three phase 3W+G | 240~277Vac | 320Vac | 80kA | L-G: 1.8kV | 2 |
DT80P/150-(3V+T)-S | 4 | Three phase 4W+G | 120~127Vac | 150Vac | 80kA | L-N: 0.8kV, N-PE: 0.8kV | 1 |
DT80P/180-(3V+T)-S | 4 | Three phase 4W+G | 120~127Vac | 180Vac | 80kA | L-N: 0.8kV, N-PE: 0.8kV | 1 |
DT80P/275-(3V+T)-S | 4 | Three phase 4W+G | 220~230Vac | 275Vac | 80kA | L-N: 1.5kV, N-PE: 1.5kV | 1 |
DT80P/320-(3V+T)-S | 4 | Three phase 4W+G | 240~277Vac | 320Vac | 80kA | L-N: 1.8kV, N-PE: 1.5kV | 1 |
DT80P/150-4V-S | 4 | Three phase 4W+G | 120~127Vac | 150Vac | 80kA | L/N-G: 0.8kV | |
DT80P/180-4V-S | 4 | Three phase 4W+G | 120~127Vac | 180Vac | 80kA | L/N-G: 0.8kV | |
DT80P/275-4V-S | 4 | Three phase 4W+G | 220~230Vac | 275Vac | 80kA | L/N-G: 1.5kV | |
DT80P/320-4V-S | 4 | Three phase 4W+G | 240~277Vac | 320Vac | 80kA | L/N-G: 1.8kV |