Class I&II, T1+T2, TUV PV Solar DC Surge Arresters

  • Class I&II, T1+T2, TUV PV Solar DC Surge Arresters
  • Class I&II, T1+T2, TUV PV Solar DC Surge Arresters
  • Class I&II, T1+T2, TUV PV Solar DC Surge Arresters
Class I&II, T1+T2, TUV PV Solar DC Surge Arresters
  • Prosurge
  • China
  • 4-5 weeks
  • 30kpcs/month

PROSURGE PV50 series (48Vdc~1500Vdc) are class I & class II (or T1+T2 ) PV DC SPD designed for DC application such as PV/ solar system dc-side surge protection. Built in high energy MOV, Iimp 7.5 kA 10/350μs, with thermal protection, quick thermal response and secure disconnection.

TUV certified (pending) T1+ T2 PV DC SPD per IEC/EN 61643-31 standard.

18mm narrow model design, prewired three poles of Y circuit for common mode & differential mode protection

Application in Photovoltaic (PV) systems and other DC power system like charging system for electric vehicles etc. 

Unique thermal disconnector design

Lightning current capacity up to 7.5 kA10/350μs

Surge current capability up to 50kA 8/20μs

Low voltage protection level 

Degradation failure indication and optional remote signal contact.

Pluggable module for easy replacement without the need to remove system wiring.

Wide operating temperature -40ºC ~85ºC

35mm DIN-rail mounting

Comply with EN 50539-11,UL1449 5th, IEEE C62.41,CSA C22.2 standards


3 Poles  100Vdc ~1500Vdc

Part No.

PV50/100-V-CD (-S)

PV50/200-V-CD(-S)

PV50/300-V-CD(-S)

PV50/400-V-CD(-S)

PV50/600-V-C(-S)

PV50/800-V-CD(-S)

PV50/1000-V-CD(-S)

PV50/1200-V-CD(-S)

PV50/1500-V-CD(-S)

In accordance with

IEC/EN 61643-31; UL1449 5th; EN 50539-11

Category IEC/EU/VDE

I+ II /1+2/ B+C

Nominal Voltage (DC)  Un

100V

200V

300V

400V

600V

800V

1000V

1200V

1500V

Max. continuous operating voltage (DC)  Ucpv

110V

250V

340V

450V

700V

920V

1120V

1340V

1500V

Nominal discharge current(8/20)  In

20kA

20kA

20kA

20kA

20kA

20kA

20kA

20kA

20kA

Max. discharge current(8/20)  Imax

50kA

50kA

50kA

50kA

50kA

50kA

50kA

50kA

50kA

Lightning impulse current (10/350)  Iimp

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

6kA

4.5kA

4.5kA

Voltage protection level  

Up (DC+/- to PE, DC+ to DC-)

1.0kV

1.2kV

1.5kV

2.0kV

2.5kV

2.8kV

3.5kV

4.0kV

4.5kV

Response time  tA

25 ns

Leakage Current  Ipe

<0.1mA

Short-circuit Current  Iscpv

25kA

Operating temperature range

- 40ºC ~ + 85ºC

Altitude

-500m ~ +4000m

Cross-section of connection wire (max)

Single-strand 35mm2; multi-strand 25mm2

Mounting

35mm DIN-rail in accordance with EN 50022/DIN46277-3

Enclosure material

thermoplastic; extinguishing degree UL94 V-0

Degree of protection

IP20

Installation width

3 modules, DIN 43880

Thermal disconnector

Internal  Green – normal ; red - failure

Remote alarm contact

Optional

Approvals, Certifications

TUV CE

Additional data for Remote Alarm Contacts

Remote alarm contact type

Isolated Form C

Switching capability Un/In

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Cross-section of remote signaling wire

Max. 1.5mm2(or # 16AWG)


2 poles 48Vdc ~600Vdc

Part No.

PV50/100-V-CD (-S)

PV50/200-V-CD(-S)

PV50/300-V-CD(-S)

PV50/400-V-CD(-S)

PV50/600-V-C(-S)

PV50/800-V-CD(-S)

PV50/1000-V-CD(-S)

PV50/1200-V-CD(-S)

PV50/1500-V-CD(-S)

In accordance with

IEC/EN 61643-31; UL1449 5th; EN 50539-11

Category IEC/EU/VDE

I+ II /1+2/ B+C

Nominal Voltage (DC)  Un

100V

200V

300V

400V

600V

800V

1000V

1200V

1500V

Max. continuous operating voltage (DC)  Ucpv

110V

250V

340V

450V

700V

920V

1120V

1340V

1500V

Nominal discharge current(8/20)  In

20kA

20kA

20kA

20kA

20kA

20kA

20kA

20kA

20kA

Max. discharge current(8/20)  Imax

50kA

50kA

50kA

50kA

50kA

50kA

50kA

50kA

50kA

Lightning impulse current (10/350)  Iimp

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

6kA

4.5kA

4.5kA

Voltage protection level  

Up (DC+/- to PE, DC+ to DC-)

1.0kV

1.2kV

1.5kV

2.0kV

2.5kV

2.8kV

3.5kV

4.0kV

4.5kV

Response time  tA

25 ns

Leakage Current  Ipe

<0.1mA

Short-circuit Current  Iscpv

25kA

Operating temperature range

- 40ºC ~ + 85ºC

Altitude

-500m ~ +4000m

Cross-section of connection wire (max)

Single-strand 35mm2; multi-strand 25mm2

Mounting

35mm DIN-rail in accordance with EN 50022/DIN46277-3

Enclosure material

thermoplastic; extinguishing degree UL94 V-0

Degree of protection

IP20

Installation width

3 modules, DIN 43880

Thermal disconnector

Internal  Green – normal ; red - failure

Remote alarm contact

Optional

Approvals, Certifications

TUV CE

Additional data for Remote Alarm Contacts

Remote alarm contact type

Isolated Form C

Switching capability Un/In

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Cross-section of remote signaling wire

Max. 1.5mm2(or # 16AWG)



1 pole 48Vdc ~750Vdc


Part No.PV50/48-V(-S)PV50/75-V(-S)PV50/100-V(-S)PV50/150-V(-S)PV50/200-V(-S)PV50/300-V(-S)PV50/400-V(-S)PV50/500-V(-S)PV50/600-V(-S)PV50/750-V(-S)
In accordance withIEC/EN 61643-31; UL1449 5th; EN 50539-11
Category IEC/EU/VDEI+ II /1+2/ B+C
Nominal Voltage (DC)  Un48V75V100V150V200V300V400V500V600V750V
Max. continuous operating voltage (DC)  Ucpv 85V100V125V170V225V350V460V560V670V800V
Nominal discharge current(8/20)  In20kA20kA20kA20kA20kA20kA20kA20kA20kA20kA
Max. discharge current(8/20)  Imax50kA50kA50kA50kA50kA50kA50kA50kA50kA50kA
Lightning impulse current (10/350)  Iimp7.5kA7.5kA7.5kA7.5kA7.5kA7.5kA7.5kA6kA4.5kA4.5kA
Voltage protection level  Up0.6 kV0.6kV0.7 kV0.8kV1.0 kV1.2 kV1.5 kV2.0 kV2.2kV2.5kV
Response time  tA≤25 ns
Leakage Current  Ipe<0.1mA
Short-circuit Current  Iscpv25kA
Operating temperature range- 40ºC ~ + 85ºC
Altitude-500m ~ +4000m
Cross-section of connection wire (max)Single-strand 35mm2; multi-strand 25mm2
Mounting35mm DIN-rail in accordance with EN 50022/DIN46277-3
Enclosure materialthermoplastic; extinguishing degree UL94 V-0
Degree of protectionIP20
Installation width1 modules, DIN 43880
Thermal disconnectorInternal  Green – normal ; red - failure
Remote alarm contactOptional
Approvals, CertificationsTUV CE
Additional data for Remote Alarm Contacts
Remote alarm contact typeIsolated Form C
Switching capability Un/InAC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A
Cross-section of remote signaling wireMax. 1.5mm2(or # 16AWG)


3 Poles SPD Circuit

TUV DC Surge Protection Device


2 Poles SPD Circuit

Solar DC surge arrester


1 Pole SPD Circuit

PV Surge Protection Device

Prosurge SPD Factory
Prosurge SPD Factory
Prosurge Surge Test Lab
Prosurge Surge Test Lab
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right