Intelligent SPD with Surge and Power Monitoring
- Prosurge
- China
- Within 25 days
- 5kpcs per month
The PROSURGE iSPD is an intelligent and auto self-protected SPD for the single phase or multi phase power systems. It’s an innovative solution for most commercial and industrial environments with critical operations, to make your surge protection smart and intelligent.
The iSPD is composed of three essential parts: surge protective device (SPD), intelligent surge & power monitor (iSPM) or Lightning/Surge event counter LEC-AT and surge circuit breaker (SCB).
PROSURGE high performance SPDs (Class I or Class II per IEC 61643-11) of iSPD can protect sensitive equipment from the harmful transient voltage surges resulting from:
Direct and indirect lightning strikes
Power company load switching
Upstream load switching at other facilities
PROSURGE iSPM/LEC-AT technology makes it easy to monitor the power & lightning protecting system. This device allows end user to monitor real time power quality for SPD and Lightning/Surge event and get alarm feedback on failure and fault from power system and device self:
SPD working status with alarm for SPD Failure, -Model: iSPM02
SPD’s aging with alarm while close to end-of-life of SPD, -Model: iSPM02
Lightning and surge event (surge polarity, time-to-event, total events quantity) , - Model: iSPM02/LEC-AT
lBuzzer alarm when the number of surge events reaches a settable number, -Model: LEC-AT
lBackup over-current protection device working status (circuit breaker or fuse) with alarm for CB or fuse open, -Model: iSPM02
lVoltage on SPD in real-time, alarm for overvoltage event, -Model: iSPM02
lGrounding conditions of SPD with alarm for Grounding fault, -Model: iSPM02
N line lost alarm (screen light off while lost, alarm by remote signal contact), -Model: iSPM02
PROSURGE SCB provides backup over-current protection for the SPD, which is fully coordinated with the surge protective device. Comparing to normal backup circuit breaker/fuse, the integrated PROSURGE SCB achieve a better balance between surge withstand performance (no tripping while expected surge occurs) and sharp reaction against short circuit and abnormal leakage current.
The iSPD can communicate with computer or smart terminal.
It can connect RS485 half-duplex MODBUS RTU protocol communication mode to the remote monitoring center.
Or through the "RS485/Ethernet converter", the MODBUS communication protocol can be converted to the Ethernet protocol, allowing the iSPD to connect to the Internet.
Once the iSPDs are connected to network, end user will be easy to get accurate and convenient information through computer software or smartphone apps, and be able to act quickly to guarantees system uninterrupted operation based on optimal information.
Brows information on PC
Typical Applications:
Commercial
Industrial
Communications
Renewable energy
Critical power (hospitals, data centers, etc)
Features:
High performance SPD inbuilt with Iimp 12.5kA 10/350 for Class I and In 20kA 8/20 for Class II application (based on the selected model), comply with IEC/EN 61643-1/11, UL1449 4th standards;
Pluggable module of SPD for easy replacement
Self protected by PROSUGE innovated Surge circuit breaker technology, SPD will never stop service in the life time and no fire risk while in the end of life
Intelligent monitor (iSPM) helps end user to know all accurate information about power system abnormal conditions in order to take action in time.
Surge events and system fault events logging, 999 events recording data (ISPM).
Buzzer alarm when the number of surge events reaches a settable number(LEC-AT)
OLED display is convenient for end user to view present or history information
With RS485 network and Ethernet, end user can control and manage the system in short or remote distance
Visual and audible alarm for several functions, like SPD degradation or Failure, abnormal Power system conditions, back up CB or Fuse open, Surge event counting to a pre-set alarm number etc.
Easy installation
IP20 enclosure to resist dirt, dust and water
Configure & Ordering Information:
iSPD | -02 | /C | 320 | -PN | -SCB |
Intelligent SPD Model series | Intelligent Surge & Power Monitor Model Series | SPD category per IEC/EN | Max. operating voltage (Uc) | SPD config | Back up Surge Circuit Breaker |
iSPD | -02 : iSPM02 -AT : LEC-AT ... | B: Class I or T1 C: Class II or T2
| 320:75VAC~320VAC
| 2: Two poles(2+0) PN: Two poles(1+1) 3: Three poles(3+0) 4: Four poles(4+0) | With or without |
Intelligent Surge & Power Monitor choice
Function | -02 | -AT |
Lightning and surge event logging and (surge polarity, time-to-event, total events quantity) | √ | √ |
Pre-set alarm number of surge event | √ | |
SPD working status with alarm | √ | |
SPD’s aging with alarm | √ | |
Backup over-current protection device working status with alarm | √ | |
Voltage on SPD in real-time with alarm | √ | |
Neutral line monitor with alarm | √ |
Model: iSPD-02/…-SCB
Technical Specification
iSPD-02/B320-PN-SCB | iSPD-02/B320-3PN-SCB | iSPD-02/C320-PN-SCB | iSPD-02/C320-3PN-SCB | |||
SPD Specification | ||||||
SPD Category IEC/EN | Class I / T1 | Class I / T1 | Class II / T2 | Class II / T2 | ||
Power System | TT/TN 1ph | TT/TN 3ph | TT/TN 1ph | TT/TN 3ph | ||
System Voltage | Un | 220/380V ~ 240/415V | ||||
Max. Continuous Operating Voltage AC | Uc | 320VAC | ||||
Lightning Impulse Current (10/350 μs) | Iimp | L-N: 12.5kA N-PE:25kA | L-N: 12.5kA N-PE:50kA | (blank) | (blank) | |
Nominal Discharge Current (8/20 μs) | In | L-N: 25kA N-PE:25kA | L-N: 25kA N-PE:50kA | 20kA | 20kA | |
Max. Discharge Current (8/20 μs) | Imax | 80kA | 80kA | 50kA | 50kA | |
Voltage Protection Level | Up | 1.5kV | 1.5kV | 1.5kV | 1.5kV | |
Residual Current | Ipe | <0.1mA | ||||
TOV- Withstand Mode | Utov | L-N:335V/5s; N-PE:1200V/200ms | ||||
Short Circuit Current Rating | Isc | 25kArms | ||||
Response Time | Ta | ≤25 ns | ||||
Thermal Disconnector / Indication | Internal red - failure | |||||
iSPM Specification or LEC-AT(alternative) | ||||||
Model | iSPM02 | LEC-AT | ||||
Display Screen | OLED screen | |||||
Event Logging | 999 events | |||||
Surge Event Counting | Counting Current ≥100A (adjustable) | |||||
RS485 | ||||||
Indication | Buzzer / Indicator/remote signal | Buzzer / Indicator | ||||
SCB Specification | ||||||
Operating Short-Circuit Breaking Capacity | Ics | ≥10kA | ||||
Trip Current | It | 3±1A | ||||
Trip Time | Tt | ≤40ms | ||||
Surge Withstand Capability | Iwt | Match with SPD Max. Surge current | ||||
General Parameters | ||||||
Connection | Connection in parallel | |||||
Connecting Cable | Power line:10-35mm2 ; Remote signal:1.5mm2 | |||||
Operation Temperature Range | -40℃~+70℃ | |||||
Humidity | 30%~90% | |||||
Degree Of Protection | IP20 | |||||
Housing Material | UL94V0 | |||||
Mounting | Wall mounting | |||||
Dimension (mm) | 3 Phase : 200*180*87 ; 1 Phase: 148*180*87 |
Dimensions (unit: mm)
iSPD for three phase (TT/TN) iSPD for single phase(TT/TN)
Typical Installation Diagram
Three phase wiring (TT/TN) Single phase wiring (TT/TN)