Panel SPD - 400kA to 900 kA per phase
- Prosurge
- China
- 30 days after receiving payment
- 3000pcs per month
PROSURGE PS series panel SPDs are defined as ultra-Large surge capacity design for mission critical application. They are high performance UL listedType 1 and Type 2 Surge Protective Devices (SPDs) that protect most commercial and industrial environments against the harmful effects of transient surges.
Features:
UL listed Type 1 (ANSI/UL1449 5th,CSA C22.2) SPDs.
UL listed Type 2 (ANSI/UL1449 5th,CSA C22.2) SPDs with Sine Wave Tracking
Surge capacity (8/20 us ):
150~600 kA per phase while built with SMTMOV(Imax:50kA) modules
225~900kA per phase while built with HSMTMOV(Imax:75kA) modules
Lightning capacity (10/350 us): 12.5~80kA per phase, EN/IEC 61643-1/11 class I test
Short Circuit current rating (SCCR): 200 kArms - tested without external CB or fuse
Full modes protection, more options in protection mode combination for specified applications
High surge energy capability with compact size
Low voltage protection rating
Three-stages degradation failure indication, Anticipatory failure monitoring (AFM) technology to ensure permanent surge protection
With remote alarm
With surge event counter
NEMA 4 metal enclosure
EN/IEC 61643-1/11 compliant
PROSURGE® PS series panel SPDs are constructed with Prosurge’s patented surge protection module (SMTMOV/HSMTMOV), which has a thermally protected and arc extinguishing technology as the core of Prosurge’s competency. PS has a significant advantage in abnormal over-voltage & high fault current safety and thus ensures industry's highest level of safety and performance. The parallel redundancy modules design makes the SPDs extremely robust and reliable, in the event of a surge protection module (SMTMOV) failure the remaining module array will continue to provide surge protection. Further this design prompt SPDs to handle great impulse current up to 600kA (8/20 μs) and multiple impulse current at its highest rated level. PS surge panel can meet most critical challenge worldwide and ensure maintenance -free for its lifetime.
The front panels integrate functionality of SPD working status monitor and self-diagnosis to enhance the performance and usability. They feature with indicator and colored LEDs to demonstrate the power & protection status of each protected power phase
Anticipatory failure monitoring (AFM) technology
The ' Anticipatory failure monitoring ' technology allows the user to exchange panel SPDs before protected electrical equipments or systems are threatened by overloads to ensure permanent surge protection. Three stages (BLUE /- YELLOW /– RED) LED visual indication can help user to judge the protection status. While the indicator light turns to YELLOW, it means the potentially anticipatory failure of the panel SPD, at this point, the user is recommended to replace the panel SPDs. If the SPDs are not replaced, also they will continue to provide limited protection, but further overloads on the SPD, such as a follow up higher or repeated discharge of lightning currents, may lead to the increased risk of surge damage.
The Prosurge PS series are tested and listed as UL1449 5th Type 1 and Type 2 SPD (with sine wave tracking function). They are constructed with NEMA 4 enclosures to ensure that dirt, dust and water are resisted for either indoor or outdoor usage.
Typical Applications in high exposure locations, be ideal for primary service or building entrances protection applications.
Commercial
Industrial
Communications
Renewable energy
Critical power (hospitals, data centers, etc)
General Specification:
PS category | D |
Certification | ANSI/UL1449 5th,CSA C22.2,Type 1,Type2 |
Connection Type | Parallel Connected |
Surge Capacity (8/20 us) | 150-600kA per Phase (PS model built with SMTMOV) 225-900kA per Phase(PS model built with HSMTMOV) |
Lightning Capacity (10/350 us) | 12.5-50kA per Phase (PS model built with SMTMOV) 20-80kA per Phase(PS model built with HSMTMOV) |
SCCR | 200kArms |
Sine wave tracking | Optional for UL Type 2 listed |
Lightning counter Current | ≥ 200A (with Reset button ) |
Failure pre-test | Press 2S (test button) |
Power Status Indication | Normal=Blue LED ON |
Working Status Indication | Three stage (Normal= Blue LED ON ; Need replace= Yellow, Fail= Turn to Red) |
Power Connecting | 8 AWG,762mm (30”) length, (L1=black ;L2=red;L3=blue; N=white; PE=green ) |
Signal cable | 16AWG, 762mm (30”) length ,C=red; NC=blue; NO=brown |
Working environments | Temperature –40℃~+85℃, Humidity relative 5~95% (25℃) , Altitude≤3km |
Dimensions, W x D x H | 350x370x223 mm |
Threaded NPT | 1” NPT |
Enclosure | Metal enclosure, NEMA 4 |
Net Weight | 10.6 kg |
Configure & Ordering Information:
PS Model
PS | 277Y Voltage and system configuration
120SP: 120/240V split 240SP:240/480V split 120Y:120/208V WYE 277Y: 277/480V WYE 120H:120/240V high leg delta 240D: 240V delta 120S:120V 1ph, 2W+G … | C Protection mode
C: Delete N-G protection mode, G: Only L/N(if need)-G protection, delete L-N and L-L (if present ) protection, N: Only L-N&N-G protection, delete L-G protection. N/A : Full mode protection | 42 Surge capacity
31: 150 or 225kA(1)per phase 41:200 or 300kA(1) per phase 51:250 or 375kA(1) per phase 61:300 or 450kA(1) per phase 32:300 or 450kA(1) per phase 42:400 or 600kA(1) per phase 52:500 or 750kA (1)per phase 62:600 or 900kA(1) per phase | T Gas Tube optional
T: Gas Tube used for N-G protection mode | / T1 SPD Category
T1: UL type 1 SPD T2F: UL type 2 SPD with sine wave tracking
| CA Additional function
C: surge event counter A: remote alarm |