63A - 125A Surge Filter
- Prosurge
- China
- 30 days after receiving payment
- 400Kpcs per month
Prosurge surge filter BSF100 is used to protect single/three phase electrical distribution systems, especially to protect sensitive electronics against the harmful effects of transient surges.
Features:
Multi-stage protection circuit with LC Filter design to protect sensitive electronics.
Provides extensive high frequency & RF filtering
Prosugre ESG+VTD technology to improve voltage clamping performance
Application for 120~127V, 220~277V (L-N) TT/TN, or single phase system with a grounded neutral
Application for 120/208 ~127/220 Vac, 220/380 to 277/480 Vac TT/TN, any 3-phase system with a grounded neutral
Protection capability 25kA 10/350us or 100kA 8/20us per mode
Surge capacity of N-PE mode up to 100kA 10/350 μs
Load current rating 63A~125A available
Built-in in series fuse for overload /short circuit protection available
All mode protection,1+1 protection circuit for TN-S and TT systems
LED failure indication & remote alarm function available and surge counter optional
Comply with UL1449 4th,IEEE C62.41, CSA C22.2,IEC/EN 61643-11
It’s found that electronic equipment is sensitive to both the absolute magnitude of the impulse voltage and its rise rate. The radical changes in dv/dt and di/dt, rather than the peak voltage, is the major source of electronic circuit damages.
Prosurge surge filter is designed as a 3-stage protection system which consists of primary protection & secondary protection and with a well-designed LC filter in series. The LC filter is used to slow down the inherently fast rise rate of voltage and current. The primary protection module is used to divert the strong lightning/surge current, while the secondary protection module & LC filter will limit the let-through voltage to a very low level.
The surge filter should be installed in series with the supply powering the equipment.
Technical data (for single phase):
Model | BSF100-1/180-63A-PN-VTD-S | BSF100-1/320-63A-PN-VTD-S | ||
According to | IEC61643-11; UL1449-4th; IEC610006; ANSI/IEEE C62.41; AS1768-1991;AS3100 | |||
Category IEC/EN/UL | Class I+II/ Type 1+2 / Type 2 | |||
Protection Mode | All mode protection | |||
Protection technology | ESG(primary)+ VTD(Secondary) tech, GDT technology for NPE mode LC filter, Thermal disconnector, Built-in over-current protection | |||
Power system | Un | 120~127V single phase | 220-277V single phase | |
Max. continuous operating voltage (AC/DC) | Uc | 180/230V | 320/420V | |
Rated load Current | Il | 63A | ||
Nominal discharge current /In | In | 25kA(8/20us) | ||
Primary surge protection rating | L-N | Iimp:25kA (10/350us), Imax:100kA (8/20us) | ||
N-PE | Iimp:100kA (10/350us), Imax:200kA(8/20us) | |||
Secondary surge protection rating | L-N | Imax | 50kA(8/20us) | |
Total surge capacity per Line | Itotol | 150kA (8/20us) | ||
Voltage protection level Up | L-N@6kV/3kA | VPR | <0.4kV | <0.5kV |
L-N@ In | Up | <0.7kV | < 0.85kV | |
N-PE@1.2/50 | Up | < 1.0kV | < 1.5kV | |
Residual Current | I PE | <0.1mA | ||
Voltage drop: | < 2V at 63 A load | |||
Temporary overvoltage TOV —Withstand mode | Utov | 230V/120min | 440VAC/120min | |
Response time | Ta | ≤1ns | ||
Filter attenuation | dB | >48dB @ 1MHz | ||
Built in over load/ over-current protection in series | 63A (optional) | |||
Lightning counter Current | ≤ 3kA | |||
Protect Status Indication
| 2 LED display, Normal (Blue), Protection fault(Off)
| |||
Remote alarm | Dry contact alarm relay – 250Vac/32Vdc, 5A | |||
Connecting cable | Power 6-8AWG(50A/63A), Alarm 14 -22AWG, | |||
Environment | Temperature Range:- 40ºC ~ +70ºC Humidity:≤95% Altitude:≤2000m | |||
Mounting | Wall mounting | |||
Location Category | Indoor | |||
Degree of protection | IP20 | |||
Dimension | 425mm (L) x370mm (W) x 170mm (H) approx | |||
Weight | 20kg approx | |||
Approvals, Certification | , | CE |
Technical data (for three phase):
Model | BSF100-3/180-63A-3PN-VTD-S | BSF100-3/320-63A-3PN-VTD-S | ||
According to | IEC61643-11; UL1449-4th; IEC610006; ANSI/IEEE C62.41; AS1768-1991;AS3100 | |||
Category IEC/EN/UL | Class I+II/ Type 1+2 / Type 2 | |||
Protection Mode | All mode protection | |||
Protection technology | TSG(primary)+ VTD(Secondary) tech, GDT Tech LC filter, Thermal disconnector, Built-in over-current protection | |||
Power system | Un | 120/208 to 127/220 Vac Three phase (TN/TT) | 220/380 to 277/480 Vac Three phase (TN/TT) | |
Max. continuous operating voltage (AC/DC) | Uc | 180/230V | 320/420V | |
Rated load Current | Il | 63A | ||
Nominal discharge current /In | In | 25kA(8/20us) | ||
Primary surge protection rating | L-N | Iimp:25kA (10/350us), Imax:100kA (8/20us) | ||
N-PE | Iimp:100kA (10/350us), Imax:200kA(8/20us) | |||
Secondary surge protection rating | L-N | Imax | 50kA(8/20us) | |
Total surge capacity per Line | Itotol | 150kA (8/20us) | ||
Voltage protection level Up | L-N@6kV/3kA | VPR | <0.4kV | <0.5kV |
L-N@ In | Up | <0.7kV | < 0.85kV | |
N-PE@1.2/50 | Up | < 1.0kV | < 1.5kV | |
Residual Current | I PE | <0.1mA | ||
Voltage drop: | < 2V at 63 A load | |||
Temporary overvoltage TOV —Withstand mode | Utov | 230V/120min | 440VAC/120min | |
Response time | Ta | ≤1ns | ||
Filter attenuation | dB | >48dB @ 1MHz | ||
Built in over load/ over-current protection in series | 63A (optional) | |||
Lightning counter Current | ≤ 3kA | |||
Protect Status Indication
| 4 LED display, Normal (Blue), Protection fault(Off)
| |||
Remote alarm | Dry contact alarm relay – 250Vac/32Vdc, 5A | |||
Connecting cable | Power 6-8AWG(50A/63A), Alarm 14 -22AWG, | |||
Environment | Temperature Range:- 40ºC ~ +70ºC Humidity:≤95% Altitude:≤2000m | |||
Mounting | Wall mounting | |||
Location Category | Indoor | |||
Degree of protection | IP20 | |||
Dimension | 520mm (L) x425mm (W) x 170mm (H) approx | |||
Weight | 30kg approx. | |||
Approvals, Certification | , | CE |